Q8. With reference to a major fire in the machinery space:
(a) explain why EACH of the following equipment is shut down remotely, stating how it is achieved;
(i) settling and service tank outlet valves;(2)
(ii) fuel transfer and supply pumps; (2)
(iii) mechanical and natural ventilation; (2)
(b) explain how the fire is brought under control using the facilities out with the affected machinery space. (4)